Filtres plissés

layer

Type MFCA

 

Final filters for the separation of suspended particles to meet the highest requirements

  • Filter classes E11, H13
  • Performance data tested to EN 1822
  • Filter media for special requirements, glass fibre papers with spacers made of thermoplastic hot-melt adhesive
  • Low initial differential pressure due to ideal pleat position and largest possible filter area

lire la suite

layer

Type FHD

 

Final filters for the separation of suspended particles, suitable for industrial, research, medical, and pharmaceutical applications

  • Filter classes E11, H13, H14, U15
  • Performance data factory tested to EN 1822
  • Filter media for special requirements, glass fibre papers with spacers made of thermoplastic hot-melt adhesive
  • Low initial differential pressure due to ideal pleat position and largest possible filter area
  • Perfect adjustment to individual requirements due to different constructions
  • Filter hood available in various sizes and the usual grid sizes
  • Automatic filter scan test for all filters from filter class H14


Optional equipment and accessories

  • Mechanism for volume flow rate setting

lire la suite

layer

Type MFE

 

Prefilters or final filters for the separation of fine dust, or particulate filters for the most critical requirements in ventilation systems

  • Filter classes F9, E11, H13
  • Performance data to EN 779 or EN 1822
  • Eurovent certification for fine dust filters
  • Filter media for special requirements, made of glass fibre papers, with spacers made of textile threads
  • Low initial differential pressure due to ideal pleat position and largest possible filter area

lire la suite

layer

Type MFC

 

Prefilters or final filters for the separation of fine dust, or particulate filters for the most critical requirements in ventilation systems

  • Filter classes M6, F7, F9, E11, H13, H14
  • Performance data to EN 779 or EN 1822
  • Eurovent certification for fine dust filters
  • Filter media for special requirements, made of glass fibre papers, with spacers made of textile threads
  • Low initial differential pressure due to ideal pleat position and largest possible filter area
  • Compact depth construction
  • Fitting into ducted particulate filters (types KSF, KSFS) and duct casings for particulate filters (type DCA)

lire la suite

layer

Type MFI

 

Prefilters or final filters for the separation of fine dust, or particulate filters for the most critical requirements in ventilation systems

  • Filter classes M5, M6, F7, F9, E10, E11, H13, H14
  • Performance data to EN 779 or EN 1822
  • Eurovent certification for fine dust filters
  • Meets the hygiene requirements of VDI 6022
  • Highest energy efficiency according to Eurovent document 4/11
  • Filter media for special requirements, glass fibre papers, with spacers made of hot-melt adhesive or textile threads
  • Low initial differential pressure due to ideal pleat position and largest possible filter area
  • Compact depth construction
  • Fitting into standard cell frames for filter walls (type SIF), into mounting frames (type MF), or into universal casings (type UCA) for duct installation

lire la suite

layer

Type MFPCR

 

HEPA and ULPA filters as high-efficiency particulate filters for the separation of suspended particles in clean room systems. Used for industrial, research, medical, pharmaceutical, and nuclear engineering applications.

  • Filter classes H14, U15, U16
  • Performance data tested to EN 1822
  • Meets the hygiene requirements of VDI 6022
  • Filter media for special requirements, glass fibre papers with spacers made of thermoplastic hot-melt adhesive
  • Perfect adjustment to individual requirements due to variable pleat depths
  • Low initial differential pressure due to ideal pleat position and largest possible filter area
  • Automatic filter scan test
  • Fitting into filter fan units, clean room workbenches, or operating theatre ceilings

lire la suite

layer

Type MFP

 

Prefilters or final filters for the separation of fine dust and suspended particles. Used for industrial, research, medical, pharmaceutical, and nuclear engineering applications.

  • Filter classes M5, M6, F7, F9, E11, H13, H14
  • Performance data tested to EN 779 or EN 1822 Meets hygiene requirements according to VDI 6022
  • Eurovent certification for fine dust filters
  • Filter media for special requirements, glass fibre papers with spacers made of thermoplastic hot-melt adhesive
  • Low initial differential pressure due to ideal pleat position and largest possible filter area
  • Perfect adjustment to individual requirements due to different pleat depths, filter frame made of various materials
  • Automatic filter scan test for all filters from filter class H14
  • Fitting into ceiling mounted or wall mounted particulate filters (types TFC, TFW, TFM, TFP), ducted particulate filters (types KSF, KSFS), duct casings for particulate filters (type DCA), or operating theatre ceilings

lire la suite

Partager la page

Recommander cette page

Recommander cette page en envoyant un lien par mail.

Les champs marqués d'un (*) sont obligatoires.

Partager la page

Merci pour votre recommandation !

Votre recommandation a été envoyée et devrait arriver dans les plus brefs délais.


Contact

Nous sommes à votre disposition

Visual contact Visual contact

Veuillez préciser votre message et le type de demande.
Tel.: +41 26 425 59 00 | Fax: +41 26 425 59 01

Les champs marqués d'un (*) sont obligatoires.

Contact

Merci pour votre message !

Visual contact Visual contact

Votre message a été envoyé et sera traité dans les plus brefs délais.
Notre département de traitement des demandes prendra contact avec vous dès que possible.
Pour les questions d'ordre général concernant les produits ou services, vous pouvez aussi nous appeler :
Tel.: +41 26 425 59 00 | Fax: +41 26 425 59 01

Contact

Nous sommes à votre disposition

Visual contact Visual contact

Veuillez préciser votre message et le type de demande.
Tel.: +41 26 425 59 00 | Fax: +41 26 425 59 01

Pièce jointe (max. 10MB)

Les champs marqués d'un (*) sont obligatoires.

Contact

Merci pour votre message !

Visual contact Visual contact

Votre message a été envoyé et sera traité dans les plus brefs délais.
Notre département de traitement des demandes prendra contact avec vous dès que possible.
Pour les questions d'ordre général concernant les produits ou services, vous pouvez aussi nous appeler :
Tel.: +41 26 425 59 00 | Fax: +41 26 425 59 01